Drive slot sensor for storage drive presence was asserted

SOLVED: Storage Drive 2: Drive slot sensor for storage - Fixya Oct 18, 2013 · 1 Answer. Re: Storage Drive 2: Drive slot sensor for storage drive... Sounds like you have a RAID. Take a look at the RAID management software and see if the RAID is degraded. If it is degraded you probably have a bad drive on your hands. Replace the drive and the RAID should rebuild. If it is not degraded. Fault: BP Drive 0: Drive Slot sensor for BP, drive fault

Hello, On both 7.x and 8.x is there somewhere I can confirm the status of the RAID 1 set. I have a firewall that I don't have physical access to and would like to check the RAID status remotely. Dell Dell Chassis Management Controller Version 4.50 User's... Read and download Dell Software Dell Chassis Management Controller Version 4.50 User's Manual | Page 242 online. Download free Dell user manuals, owners manuals, instructions, warranties and installation guides, etc. SNMP and PET Message Reference Information - Oracle Integrated... SNMP and PET Message Reference Information. This section describes Simple Network Management Protocol (SNMP) and Platform Event Trap (PET) messages that are generated by devices being monitored by Oracle ILOM.. SNMP Traps. PET Event Messages. SNMP Traps. SNMP Traps are generated by the SNMP agents that are installed on the SNMP devices being managed by Oracle ILOM. [SOLVED] ProLiant DL380p Gen8 HD-Max Sensor Overheat issue - HPE... They have 1x 12bay SFF drives with 6 drives in slots 1 through to 6. We are using Smart Array P420i controller. We have had a drive failure on this array we believe and he have replaced the HP 1.2TB 10k SAS drive with a replacement HGST drive. I do not believe the drives temp sensors on the drives or smart data to be of issue.

Problem for server dell edge. | Tom's Hardware Forum

Sensor ID : PCI Riser 1 (0x89) Entity ID : 11.2 (Add-in Card) Sensor Type (Discrete): Entity Presence States Asserted : Entity Presence.[Drive Present] Assertions Enabled : Drive Slot. IPMI PET to Platform | Assert/ Deassert Assert Table 7 – Drive Bay Slot Sensor PET to Platform Message Registry Mapping.Assert Deassert. Event Message Label. Drive Presence Drive Presence Drive Fault. 1764-slot X Drive Array - Capacity Expansion Process Is

...1768-slot X Drive Array - Resuming Logical Drive Expansion Process; Slot X Drive Array - Drive(s) Disabled Due To Failure During Capacity Expansion264. HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide. 1764- Slot X Drive Array - Capacity Expansion Process is.

Mean drive is offline, does not means the HDD is damaged but is no longer detected, however could be related to a physical component. Try run diagnostics, make sure it pass and just rebuild it if it fails or does not rebuild properly contact Dell to avoid data lost. raid - Backplane Degraded on Dell Poweredge 2950 but non ... On Connector 0 and connector 1 there is a warning triangle next to "Enclosure (Backplane)" – audiopleb Sep 14 '10 at 11:06. The log says Storage Drive 4: Drive slot sensor for storage, drive fault was asserted. – audiopleb Sep 14 '10 at 11:06. So the problem is disk in slot #4. – lg. Cisco UCS C-Series Integrated Management Controller CLI ... Book Title. Cisco UCS C-Series Integrated Management Controller CLI Configuration Guide for C3X60 Servers . Chapter Title. Viewing Faults and Logs. PDF - Complete Book (4.62 MB) PDF - This Chapter (1.34 MB) View with Adobe Reader on a variety of devices

Cisco UCS C-Series Servers Integrated Management

Nimble Storage | Solid State Drive | Hard Disk Drive Drive Layout Secondary Flash Arrays and SF Expansion Shelves Cache: 3x Dual Flash CarriersQuality of Service in Nimble Storage Simple to Manage Flexible Limits No Licensing Unlike mostPredictive Analytics Close the App-Data Gap Cloud-based Predictive Analytics Millions of Sensors... Advertised vs. Actual Hard Drive Storage

So in this drive slot sensor, the only events are 'Drive Presence' and > > ' Drive Fault' (similarly it outputs 'OK' b/c there is no drive here). > > > > In newer FreeIPMIs there is an option --output-sensor-state that will > > map all of the errors into either NOMINAL, WARNING, or CRITICAL...

Problems using RAIDar to access a storage system . ..... Is the disk drive module “ Fault” LED amber? ...... 26 Cooling fan sensor descriptions . ...... When you have confirmed a drive fault, record the drive's enclosure number and slot number. ...... Expander Controller (EC) assert data and stack-dump data have been cleared. ThinkServer RD650 User Guide and Hardware Maintenance Manual Your server supports one of the following storage drive configurations: Drive bay size ... Three PCI Express (PCIe) slots on system board. • Three or two PCIe ... buses, sensors, the BIOS, and server management firmware. ..... The THERMTRIP# signal is asserted ... management program for server presence detection. Status. System Event Log Troubleshooting Guide for PCSD ... - Symkloud.com

System Event Log Troubleshooting 12.3 HSC Drive Presence Sensor.Different types of sensors built into the computer system report to the BMC on parameters such as temperature, cooling fan speeds, power mode, operatingEvent Type Type of trigger for the event, for example, critical threshold going high, state asserted, and so on. Re: [Freeipmi-users] HP iL03 1.5 adds support for Drive… So in this drive slot sensor, the only events are 'Drive Presence' and > > ' Drive Fault' (similarly it outputs 'OK' b/c there is no drive here). > > > > In newer FreeIPMIs there is an option --output-sensor-state that will > > map all of the errors into either NOMINAL, WARNING, or CRITICAL... How to Replace PERC ROMB Battery (Battery sensor for … Ensure your PERC 5/I RAID Adapter functions smoothly with the Dell™ 7 WHr Lithium Ion Primary Battery. This battery ensures that your SAS RAID controller pro... Ubuntu Manpage: ipmi_monitoring_sensors.conf - specify …